The cylindrical combustor considered in this tutorial is shown in Figure
14.1. The flame
considered is a turbulent diffusion flame. A small nozzle in the center of the combustor introduces methane at 80
. Ambient air enters the combustor coaxially at 0.5
. The overall equivalence ratio is approximately 0.76 (approximately 28
excess air). The high-speed methane jet initially expands with little interference from the outer wall, and entrains and mixes with the low-speed air. The Reynolds number based on the methane jet diameter is approximately
.