[ANSYS, Inc. Logo] return to home search
next up previous contents

Problem Description

The problem to be considered is shown schematically in Figure  26.1. A cold fluid at 20 $^\circ{\rm C}$ flows into the pipe through a large inlet, and mixes with a warmer fluid at 40 $^\circ{\rm C}$ that enters through a smaller inlet located at the elbow. The pipe dimensions are in inches, and the fluid properties and boundary conditions are given in SI units. The Reynolds number for the flow at the larger inlet is 50,800, so a turbulent flow model will be required.

Figure 26.1: Problem Specification
figure


next up previous contents Previous: Prerequisites
Up: Parallel Processing
Next: Preparation