Step 7: Time-Dependent Solution Setup
1. Enable a time-dependent calculation.
General
(a) Select
Transient
from the
Time
list in the
General
task page.
2. Set the solution parameters.
Solution Methods
(a) Retain the default selection of
First Order Implicit
from the
Transient Formulation
drop-down list in the
Solution Methods
task page.
Dynamic mesh simulations currently work only with first-order time advancement.